PSM Marine Instrumentation APT 1000 ...
The APT 1000 provides a reduced weight and size compared to previous generations and takes full advantage of advances in electronic design and sensing technology to provide enhanced accuracy and stability under varying operating temperatures. Body construction is all laser welded and internally encapsulated, eliminating any possibility of leaks, and all versions are IP68 certified suitable for full immersion to a minimum of 50 Metres WG. A choice of construction materials, Stainless Steel, Titanium, and Hastelloy, ensure corrosion resistance in all applications and all measurement ranges will tolerate an overload of 2 x nominal range with no adverse effects to performance or calibration.
The transmitters electronics are fully integrated within the body and incorporate a powerful micro-controller to precisely monitor and process the output of the pressure cell. On-board non-volatile memory allows each transmitter to be fully configured for its intended duty either during manufacture or subsequently while in operation.
Applications for this product
Features of this product
Why Choose This Product
ATP 1000 Specifications:
Materials | Sensor Body | 316L Stainless Steel or Titanium. Hastelloy C276316L Stainless Steel or Titanium. Hastelloy C276option for Wetted parts for external (to tank) mounting | |
Diaphragm | 316L or Titanium to match body material. Hastelloy316L or Titanium to match body material. HastelloyC276 process ports use Tantalum diaphragm. | ||
Standard Measurement Ranges (Bar) | 0.2, 0.5, 1.0, 2.5, 4.0, 10, 25, 40, 60. | ||
Measurement type | Vented Gauge or Absolute (Absolute version minimum range 1 bar) | ||
Overload | 2 x Nominal range with no effect | ||
Burst Pressure | 15 x Nominal range up to 10 Bar. 7 x Nominal range above 10 Bar | ||
Turndown | 5:1 from Nominal range (relevant to 4-20mA scaling only) | ||
Temperature measurement span/accuracy | 0 to +85°C +/- 1°C (reading only available in digital mode) | ||
Total Error Band (pressure monitoring) | +/- 0.1% of Nominal range including thermal effect | ||
Thermal compensation | No thermal effect within the range 0 to 70°C | ||
Long term stability | Error not exceeding +/- 0.1% Per Annum | ||
Max / Min process temperature | -20 to +85°C | ||
IP Rating | IP68 suitable for continuous immersion | ||
IEXEx certification | IECEx ITS 19.00023X Ex ia IIC T4 Ga -35°C≤Ta≤+85°C | ||
ATEX certification | ITS19ATEX204962X Iss.0 E x ia II C T4 Ga -3 5 °C≤Ta≤+85°C | ||
Signal Output / Power supply | 4-20mA & RS4854-20mA & RS485ModbusRTU/10 to 30V DC | ||
Maximum load | Supply dependant. Vs-10/0.02 = Load in Ohms | ||
Reverse polarity protection | Yes | ||
Weight | 0.3Kg typical for body. Cable 0.1Kg / metre |
To contact HMA Group about PSM Marine Instrumentation APT 1000 Intelligent Hydrostatic Marine Level Transmitter use Get a quote.
The APT 1000 provides a reduced weight and size compared to previous generations and takes full advantage of advances in electronic design and sensing technology to provide enhanced accuracy and stability under varying operating temperatures. Body construction is all laser welded and internally encapsulated, eliminating any possibility of leaks, and all versions are IP68 certified suitable for full immersion to a minimum of 50 Metres WG. A choice of construction materials, Stainless Steel, Titanium, and Hastelloy, ensure corrosion resistance in all applications and all measurement ranges will tolerate an overload of 2 x nominal range with no adverse effects to performance or calibration.
The transmitters electronics are fully integrated within the body and incorporate a powerful micro-controller to precisely monitor and process the output of the pressure cell. On-board non-volatile memory allows each transmitter to be fully configured for its intended duty either during manufacture or subsequently while in operation.
Applications for this product
Features of this product
Why Choose This Product
ATP 1000 Specifications:
Materials | Sensor Body | 316L Stainless Steel or Titanium. Hastelloy C276316L Stainless Steel or Titanium. Hastelloy C276option for Wetted parts for external (to tank) mounting | |
Diaphragm | 316L or Titanium to match body material. Hastelloy316L or Titanium to match body material. HastelloyC276 process ports use Tantalum diaphragm. | ||
Standard Measurement Ranges (Bar) | 0.2, 0.5, 1.0, 2.5, 4.0, 10, 25, 40, 60. | ||
Measurement type | Vented Gauge or Absolute (Absolute version minimum range 1 bar) | ||
Overload | 2 x Nominal range with no effect | ||
Burst Pressure | 15 x Nominal range up to 10 Bar. 7 x Nominal range above 10 Bar | ||
Turndown | 5:1 from Nominal range (relevant to 4-20mA scaling only) | ||
Temperature measurement span/accuracy | 0 to +85°C +/- 1°C (reading only available in digital mode) | ||
Total Error Band (pressure monitoring) | +/- 0.1% of Nominal range including thermal effect | ||
Thermal compensation | No thermal effect within the range 0 to 70°C | ||
Long term stability | Error not exceeding +/- 0.1% Per Annum | ||
Max / Min process temperature | -20 to +85°C | ||
IP Rating | IP68 suitable for continuous immersion | ||
IEXEx certification | IECEx ITS 19.00023X Ex ia IIC T4 Ga -35°C≤Ta≤+85°C | ||
ATEX certification | ITS19ATEX204962X Iss.0 E x ia II C T4 Ga -3 5 °C≤Ta≤+85°C | ||
Signal Output / Power supply | 4-20mA & RS4854-20mA & RS485ModbusRTU/10 to 30V DC | ||
Maximum load | Supply dependant. Vs-10/0.02 = Load in Ohms | ||
Reverse polarity protection | Yes | ||
Weight | 0.3Kg typical for body. Cable 0.1Kg / metre |