PROFIBUS DPV1 Master/Slave for ControlLogix ...
The ILX56-PBM PROFIBUS DPV1 Master/Multi-Slave module allows Rockwell Automation® ControlLogix® processors to communicate with various PLCs and devices using the PROFIBUS DP protocol. As a PROFIBUS DP Master, the module can transfer up to 5000 bytes of cyclic I/O data with various slave devices on the network.
Or you can use the module as a PROFIBUS DP multi-slave, where the module can emulate up to 10 individual nodes on a PROFIBUS DP network, allowing for more cyclic I/O data transfer.
With the ILX56-PBM module, ControlLogix® processors can easily communicate with devices supporting PROFIBUS DPV0 and DPV1 protocol. And through premier integration tools such as a custom Add-On Profile, project-specific Add-On Routines, and advanced tools such as PROFIBUS DP packet capture utility, you can minimize the time required to get a PROFIBUS DP network configured in a ControlLogix® environment.
In addition, with the use of multiple I/O connections back to the ControlLogix® processor, this module provides data update rates that will meet even the most demanding applications.
Features and Benefits
PROFIBUS DP Master Specifications
Specification |
Description |
Slaves |
Maximum 125 |
Input/Output |
Maximum 244 Bytes per Slave |
Input Data |
Maximum 5000 Bytes |
Acyclic Data |
DPV1 |
Status data |
88 Bytes |
Output data |
Maximum 5000 Bytes |
DPV1 Services |
Class 1 Read/Write |
Services |
Global-Control, Slave-Diagnostic, Set-Parameter |
Sync, Freeze Command |
Supported |
Baud rate |
9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud |
PROFIBUS DP Slave Specifications
Specification |
Description |
Slaves |
Emulate up to 10 slaves |
Input/Output |
Maximum 244 Bytes per Slave |
Input Data |
Maximum 2440 Bytes |
Acyclic Data |
DPV1 |
Status data |
88 Bytes |
Output data |
Maximum 2440 Bytes |
DPV1 Services |
Class 1 Read/Write, Class 1 Alarm |
Services |
Global-Control, Slave-Diagnostic, Set-Parameter |
Sync, Freeze Command |
Supported |
Baud rate |
9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud. Auto-detection mode is supported |
To contact Prosoft Technology about PROFIBUS DPV1 Master/Slave for ControlLogix use Get a quote.
The ILX56-PBM PROFIBUS DPV1 Master/Multi-Slave module allows Rockwell Automation® ControlLogix® processors to communicate with various PLCs and devices using the PROFIBUS DP protocol. As a PROFIBUS DP Master, the module can transfer up to 5000 bytes of cyclic I/O data with various slave devices on the network.
Or you can use the module as a PROFIBUS DP multi-slave, where the module can emulate up to 10 individual nodes on a PROFIBUS DP network, allowing for more cyclic I/O data transfer.
With the ILX56-PBM module, ControlLogix® processors can easily communicate with devices supporting PROFIBUS DPV0 and DPV1 protocol. And through premier integration tools such as a custom Add-On Profile, project-specific Add-On Routines, and advanced tools such as PROFIBUS DP packet capture utility, you can minimize the time required to get a PROFIBUS DP network configured in a ControlLogix® environment.
In addition, with the use of multiple I/O connections back to the ControlLogix® processor, this module provides data update rates that will meet even the most demanding applications.
Features and Benefits
PROFIBUS DP Master Specifications
Specification |
Description |
Slaves |
Maximum 125 |
Input/Output |
Maximum 244 Bytes per Slave |
Input Data |
Maximum 5000 Bytes |
Acyclic Data |
DPV1 |
Status data |
88 Bytes |
Output data |
Maximum 5000 Bytes |
DPV1 Services |
Class 1 Read/Write |
Services |
Global-Control, Slave-Diagnostic, Set-Parameter |
Sync, Freeze Command |
Supported |
Baud rate |
9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud |
PROFIBUS DP Slave Specifications
Specification |
Description |
Slaves |
Emulate up to 10 slaves |
Input/Output |
Maximum 244 Bytes per Slave |
Input Data |
Maximum 2440 Bytes |
Acyclic Data |
DPV1 |
Status data |
88 Bytes |
Output data |
Maximum 2440 Bytes |
DPV1 Services |
Class 1 Read/Write, Class 1 Alarm |
Services |
Global-Control, Slave-Diagnostic, Set-Parameter |
Sync, Freeze Command |
Supported |
Baud rate |
9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud. Auto-detection mode is supported |
To contact Prosoft Technology about PROFIBUS DPV1 Master/Slave for ControlLogix use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.