Controls Concrete Testing Machine | PILOT ...
MAIN FEATURES
Smart automatic and connected concrete Power and Control System for standard failure testing.
The machines consist of:
ORDERING INFORMATION
Note: rigid front door and pedestal are not included but available as accessories.
TECHNICAL SPECS
PILOT PRO AUTOMATIC POWER AND CONTROL SYSTEM
Hydraulics
Hardware
Firmware
PHYSICAL SPECIFICATION TABLE
Model 50- | C13P02 C13P04 |
C23P02 C23P04 |
C34P02 C34P04 |
Capacity kN (lbf) | 1500 | 2000 | 3000 |
Max vertical daylight, mm | 340 | 350 | 350 |
Horizontal daylight, mm | 265 | 340 | 370 |
Max. piston travel, mm | 50 | 50 | 50 |
Platen dimensions, mm | dia. 216 | dia. 220 | dia. 300 |
Platen surface hardness | 55.5 HRC (600 HV) | 55.5 HRC (600 HV) | 55.5 HRC (600 HV) |
Platens flatness toll, mm | 0.03 | 0.03 | 0.03 |
Overall dimensions, mm | 760 x 370 x 1085 | 835 x 440 x 1090 | 765 x 450 x 1160 |
Weight approx., kg | 315 | 530 | 760 |
UPGRADING OPTIONS
(To be specified at time of order: these items has to be factory installed.)
Frame Pedestal
Accessories suitable for 50- | C13xxx | C23xxx | C34xxx |
Frame pedestal (optional) | 50-A19/B | 50-C29/B | 50-C39/B |
Front Door
Accessories suitable for 50- | C13xxx | C23xxx | C34xxx |
Front door (optional) | 50-A19/FG | 50-C29/FG | 50-C39/FG |
Fragment guard lock switch
50-C50/P1
Fragment guard lock switch. To prevent test execution with the front door open.
Serial printer
50-Q60P/PR
Upgrade of PILOT PRO system to incorporate a serial graphic printer in the rear panel, allowing results (including a load/time plot) to be printed at the end of test
Second and third frame connection
The PILOT PRO System can be upgraded with a hydraulic valve for controlling (not simultaneously) a second and third frame.
Note: when connecting a low capacity frame (i.e. flexural or cement) pressure regulator 65-L1400/X5 may be necessary.Please ask our technical department.
50-C10C/2F
Two-way valve for PILOT PRO System to control a second frame. This item must be factory installed.
50-C10C/3F
Three-way valve for PILOT PRO System to control a second and third frame. This item must be factory installed.
Special calibration procedure
50-C0050/CAL
Special calibration of compression testers assuring Grade A from 1% to full load range.
Software
50-SW/DM
Datamanager PC Software suitable for remote control of the machine, data acquisition, processing and filing. Allows printout of customized test certificates.
To contact Geo-Con about Controls Concrete Testing Machine | PILOT PRO use Get a quote.
MAIN FEATURES
Smart automatic and connected concrete Power and Control System for standard failure testing.
The machines consist of:
ORDERING INFORMATION
Note: rigid front door and pedestal are not included but available as accessories.
TECHNICAL SPECS
PILOT PRO AUTOMATIC POWER AND CONTROL SYSTEM
Hydraulics
Hardware
Firmware
PHYSICAL SPECIFICATION TABLE
Model 50- | C13P02 C13P04 |
C23P02 C23P04 |
C34P02 C34P04 |
Capacity kN (lbf) | 1500 | 2000 | 3000 |
Max vertical daylight, mm | 340 | 350 | 350 |
Horizontal daylight, mm | 265 | 340 | 370 |
Max. piston travel, mm | 50 | 50 | 50 |
Platen dimensions, mm | dia. 216 | dia. 220 | dia. 300 |
Platen surface hardness | 55.5 HRC (600 HV) | 55.5 HRC (600 HV) | 55.5 HRC (600 HV) |
Platens flatness toll, mm | 0.03 | 0.03 | 0.03 |
Overall dimensions, mm | 760 x 370 x 1085 | 835 x 440 x 1090 | 765 x 450 x 1160 |
Weight approx., kg | 315 | 530 | 760 |
UPGRADING OPTIONS
(To be specified at time of order: these items has to be factory installed.)
Frame Pedestal
Accessories suitable for 50- | C13xxx | C23xxx | C34xxx |
Frame pedestal (optional) | 50-A19/B | 50-C29/B | 50-C39/B |
Front Door
Accessories suitable for 50- | C13xxx | C23xxx | C34xxx |
Front door (optional) | 50-A19/FG | 50-C29/FG | 50-C39/FG |
Fragment guard lock switch
50-C50/P1
Fragment guard lock switch. To prevent test execution with the front door open.
Serial printer
50-Q60P/PR
Upgrade of PILOT PRO system to incorporate a serial graphic printer in the rear panel, allowing results (including a load/time plot) to be printed at the end of test
Second and third frame connection
The PILOT PRO System can be upgraded with a hydraulic valve for controlling (not simultaneously) a second and third frame.
Note: when connecting a low capacity frame (i.e. flexural or cement) pressure regulator 65-L1400/X5 may be necessary.Please ask our technical department.
50-C10C/2F
Two-way valve for PILOT PRO System to control a second frame. This item must be factory installed.
50-C10C/3F
Three-way valve for PILOT PRO System to control a second and third frame. This item must be factory installed.
Special calibration procedure
50-C0050/CAL
Special calibration of compression testers assuring Grade A from 1% to full load range.
Software
50-SW/DM
Datamanager PC Software suitable for remote control of the machine, data acquisition, processing and filing. Allows printout of customized test certificates.
To contact Geo-Con about Controls Concrete Testing Machine | PILOT PRO use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product