The TUS Series batteries are pure lead and are of new and unique bi-polar technology.
Description
In Stock
They are designated for stationary back-up of highly critical loads. The TUS batteries are especially effective at short time of discharge as they offer much higher (20C) than the traditional batteries output within 1min to 15min back up time. That allows to build much smaller, comparing to the traditional battery, battery bank. The TUS battery can be recharged in extremely short time, which is important, should the battery be discharged after the outage and in the case of second grid failure happening soon after the first one. Such situations are frequent occurrence, and the TUS will be ready at 80% of capacity to protect the installation, after just 20 minutes of recharge at high rate. The TUS batteries have a high cyclic life which allows for increased service time – as the battery can protect the load for greater number of outages. The TUS are recommended to UPS, Energy Power Storage, data centers etc. with 1 to 15 minutes back-up times, as well as FM energy storage with high power output requirements.
Features and Benefits
Fast recharge to 100% :105 min by 2C; 75 min by 3C; 20 min to 80% by 3C)
Long cyclic life: 2,000 Cycles @70%DoD
Long float life
Design life up to 12 years
Simple Monitoring
Unlimited Number of Parallel Strings
Fire Safe
Fully Recyclable
Exceptionally High Discharge Ability from 1 to 15 min
Shock and Vibration Resistant
Standards
IEC 60896-21/22
GB/T19638
JIS C8704
BS6290 part 4
EUROBAT guide
UL1989
Applications
UPS
Energy Power Storage
Datacenters with 1 to 15 minutes back-up times
FM energy storage with high power output requirements
To contact Aeson Power about Aeson Power Bi-Polar Industrial Batteries | TUS12-420W use Get a quote.
They are designated for stationary back-up of highly critical loads. The TUS batteries are especially effective at short time of discharge as they offer much higher (20C) than the traditional batteries output within 1min to 15min back up time. That allows to build much smaller, comparing to the traditional battery, battery bank. The TUS battery can be recharged in extremely short time, which is important, should the battery be discharged after the outage and in the case of second grid failure happening soon after the first one. Such situations are frequent occurrence, and the TUS will be ready at 80% of capacity to protect the installation, after just 20 minutes of recharge at high rate. The TUS batteries have a high cyclic life which allows for increased service time – as the battery can protect the load for greater number of outages. The TUS are recommended to UPS, Energy Power Storage, data centers etc. with 1 to 15 minutes back-up times, as well as FM energy storage with high power output requirements.
Features and Benefits
Fast recharge to 100% :105 min by 2C; 75 min by 3C; 20 min to 80% by 3C)
Long cyclic life: 2,000 Cycles @70%DoD
Long float life
Design life up to 12 years
Simple Monitoring
Unlimited Number of Parallel Strings
Fire Safe
Fully Recyclable
Exceptionally High Discharge Ability from 1 to 15 min
Shock and Vibration Resistant
Standards
IEC 60896-21/22
GB/T19638
JIS C8704
BS6290 part 4
EUROBAT guide
UL1989
Applications
UPS
Energy Power Storage
Datacenters with 1 to 15 minutes back-up times
FM energy storage with high power output requirements