Novatech Controls Gas Analyser | Combustion ...
The Novatech 1732 Oxygen Transmitter is designed to measure oxygen concentration in a range of combustion applications such as power stations and industrial boilers. The measurement is used to control the air / fuel ration in the burner to maintain efficiency and safe operation conditions.
Optimum combustion reduces your fuel bill and helps the whole world and future generations by reducing harmful greenhouse gas emissions. The current high cost of fuel has helped to reduce the payback period for the cost of installing oxygen monitoring and air / fuel ratio control.
The transmitter is designed to be used along with the range of Novatech heated and unheated oxygen probes. These probes use a zirconia sensor operating in environments up to 1400° (2010°F). The 1231 oxygen probe has an integrated heater, while the 1232 probe uses the process heat to heat the sensor. There is a unique cable connection between the 1732 transmitter and the 1231/1232/1234 probe.
It makes sense to consider the benefits of installing an oxygen system on your combustion process. The 1732 Oxygen Transmitter is suitable for gaseous oxygen measurements in a variety of processes.
Features of this product
Why choose the 1732
Applications for this product
Boilers
• Power generation
• Package
• Black liquor recovery
Iron & steel
• Heating furnaces
• Coke ovens
• Soaking pits
Aluminium
• Potlines
• Holding furnaces
Incinerators
• PVC
• Medical waste
• Toxic waste
Kilns & furnaces
• Rotary lime
• Cement
• Glass
• Ceramic
• Brick
Nitrogen purity
• Generator
O2 enrichment
• Generator
Food packaging
• Continuous monitoring
Specifications
Number of Oxygen Probes: 1 or 2
Oxygen Range: 1 x 10^-30 to 100%
Oxygen Accuracy: ±1% of actual measured oxygen value with a repeatability of ±0.5% of the
measured value
Thermocouple Types: Type K and J
Temperature Accuracy: ±2?C
Analog Outputs: 0-20mA or 4-20mA field selectable
Active Outputs
Output Load: 1000 ohm max
Alarm Relays: 4
Alarm Relay Contacts: 2A 240VAC, 2A 30VDC, Reinforced insulation when used with mains voltage
Mains Voltage Supply: 100 to 240VAC 50/60 Hz Reinforced insulation
Overvoltage: Category II (IEC60364-4-443)
Power: 5 Watts for controller plus probe power, 530W max., 25% duty cycle each probe on 240VAC
110W max., 100% duty cycle each probe on 110VAC, 576W (2.4A) max
Environmental Rating: Operating Temperature -25°C to 55°C , Relative Humidity 5% to 95% (non-condensing)
Altitude: 2000m Maximum
Degree of Protection: IP65 , IP54 with internal reference air pump
Case Size: 315mm (12.4”) wide, 190mm (7.5”) high, 110mm (4.3”) deep
Case Weight: 3.3 Kg (7.3 lbs.)
To contact Intelligent Systems Pty Ltd about Novatech Controls Gas Analyser | Combustion | Flue Gas | 1732 use Get a quote.
The Novatech 1732 Oxygen Transmitter is designed to measure oxygen concentration in a range of combustion applications such as power stations and industrial boilers. The measurement is used to control the air / fuel ration in the burner to maintain efficiency and safe operation conditions.
Optimum combustion reduces your fuel bill and helps the whole world and future generations by reducing harmful greenhouse gas emissions. The current high cost of fuel has helped to reduce the payback period for the cost of installing oxygen monitoring and air / fuel ratio control.
The transmitter is designed to be used along with the range of Novatech heated and unheated oxygen probes. These probes use a zirconia sensor operating in environments up to 1400° (2010°F). The 1231 oxygen probe has an integrated heater, while the 1232 probe uses the process heat to heat the sensor. There is a unique cable connection between the 1732 transmitter and the 1231/1232/1234 probe.
It makes sense to consider the benefits of installing an oxygen system on your combustion process. The 1732 Oxygen Transmitter is suitable for gaseous oxygen measurements in a variety of processes.
Features of this product
Why choose the 1732
Applications for this product
Boilers
• Power generation
• Package
• Black liquor recovery
Iron & steel
• Heating furnaces
• Coke ovens
• Soaking pits
Aluminium
• Potlines
• Holding furnaces
Incinerators
• PVC
• Medical waste
• Toxic waste
Kilns & furnaces
• Rotary lime
• Cement
• Glass
• Ceramic
• Brick
Nitrogen purity
• Generator
O2 enrichment
• Generator
Food packaging
• Continuous monitoring
Specifications
Number of Oxygen Probes: 1 or 2
Oxygen Range: 1 x 10^-30 to 100%
Oxygen Accuracy: ±1% of actual measured oxygen value with a repeatability of ±0.5% of the
measured value
Thermocouple Types: Type K and J
Temperature Accuracy: ±2?C
Analog Outputs: 0-20mA or 4-20mA field selectable
Active Outputs
Output Load: 1000 ohm max
Alarm Relays: 4
Alarm Relay Contacts: 2A 240VAC, 2A 30VDC, Reinforced insulation when used with mains voltage
Mains Voltage Supply: 100 to 240VAC 50/60 Hz Reinforced insulation
Overvoltage: Category II (IEC60364-4-443)
Power: 5 Watts for controller plus probe power, 530W max., 25% duty cycle each probe on 240VAC
110W max., 100% duty cycle each probe on 110VAC, 576W (2.4A) max
Environmental Rating: Operating Temperature -25°C to 55°C , Relative Humidity 5% to 95% (non-condensing)
Altitude: 2000m Maximum
Degree of Protection: IP65 , IP54 with internal reference air pump
Case Size: 315mm (12.4”) wide, 190mm (7.5”) high, 110mm (4.3”) deep
Case Weight: 3.3 Kg (7.3 lbs.)
To contact Intelligent Systems Pty Ltd about Novatech Controls Gas Analyser | Combustion | Flue Gas | 1732 use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product