The DM66 provides a comprehensive feature set including low impedance (LoZ) mode, frequency, diode, capacitance, and a Type K thermocouple input for temperature measurement. The multimeter combines rich features, precise measurements, and quality construction into a tool of exceptional value. Easy to use and built to last, the DM66 offers long-term stability for everyday use.
-
All the Features You Need
Provides rich features for various electrical applications including AC/DC measurement, safe non-contact voltage detection, a flashing backlight, and audible indicator.
-
Quick, Efficient Testing and Troubleshooting
Navigate the meter’s on-screen menu system easily, and operate one-handed thanks to the compact design and easy-to-access buttons.
-
High Quality, Tough, Reliable
The DM66 is drop-tested, IP40 rated, and has a CAT IV-300V, CAT III-600V safety category rating to ensure safe and accurate operation.
Specifications | |
Measurement & Analysis | |
AC/DC LoZ V | Range: 600.0 V Basic Accuracy: ±2.0% |
AC/DC mAmps | Range: 600.0 mA Basic Accuracy: ±1.0% / ±0.7% |
AC/DC microAmps | Range: 6000 µA Basic Accuracy: ±1.5% / ±1.0% |
AC/DC mVolt | Range: 600.0 mV Basic Accuracy: ±1% / ±0.4% |
AC/DC Voltage | Range: 600.0 V Basic Accuracy: ±1.0% / ±0.4% |
Capacitance | Range: Basic Accuracy: 200.0 nF ±1.5% 200.0 µF ±1.5% 10 mF ±4.5% 10.00 mF ±5.0% |
Diode Test | Range: 3.000 V Basic Accuracy: ±0.9% |
Frequency Range | Range: 99.99 kHz Basic Accuracy: ±1.0% |
Resistance | Range: Basic Accuracy: 600.0 kO ±0.5% 6.00 MO ±0.3% 60.00 MO ±0.9% |
Thermocouple | –40 to 752.0°F DMM ± (1.0% + 3°F), –40 to 400°C DMM ± (1.0% + 1.5°C) |
VFD AC Voltage | Range: 600.0 V RMS Basic Accuracy: ±1.0% |
AC/DC Amps | Range: 10.00 A Basic Accuracy: ±1.5% / ±1.0% |
Continuity check | Between 30 O and 480 O |
True RMS | Yes |