Anton Paar Dynamic Shear Rheometer | ...
The well-established SmartPave dynamic shear rheometers are able to analyze unmodified and modified asphalt binder and bitumen within a wide temperature range, either according to standards or by means of classic rheological methods. While SmartPave 102e is the instrument which meets the highest measurement demands, SmartPave 92 is designed especially for the demands of quality control and routine measurements in asphalt test labs.
RheoCompass is a navigation tool that gives you the complete overview as well as the exact insights you require. It contains numerous templates that are tailored specifically to the needs of the asphalt industry. The predefined test procedures contain step-by-step instructions for all test types as defined by AASHTO, ASTM, DIN EN, and FGSV.
SmartPave 92’s and SmartPave 102e’s unique temperature control unit is the first Peltier heating system with heating elements above and below the sample. Furthermore, the instruments feature Toolmaster™ – the only completely contact-free automatic tool recognition and configuration system for rheometers. It recognizes measuring systems and temperature control units as soon as they are connected to the rheometer. Entering your data manually will become a thing of the past.
Anton Paar offers fully automatic temperature calibration and verification routines in the RheoCompass software. Temperature accuracy and stability are crucial in asphalt testing. The unique automatic temperature calibration routine ensures temperature gradients <0.1 °C.
Enhance your SmartPave 102e or 92 with a specialized software solution from our cooperation partner, Pavement Systems LLC. Connect effortlessly to this external analysis software and unlock a range of features, including iCCL testing. This is a powerful surrogate method to BBR (AASHTO PP112), which gives you information about the low temperature PG-grade as well as m-value, S, and delta TC within 30 minutes. Learn more about Pavement Systems and their analysis solutions.
Anton Paar’s worldwide service network ensures that an expert on your system is always close by. Numerous installed instruments around the globe, an extensive application database, and cooperation with civil engineering institutes confirm that Anton Paar is the first choice for answering any rheological question on your asphalt binder and bitumen you might have.
Technical Data | Unit | SmartPave 92 | SmartPave 102e |
Bearing design | - | Air, fine-pored carbon | |
Motor design | - | Electronically Commutated (EC) - Permanent Magnet Synchronous Motor | |
Displacement transducer design | - | High-resolution optical encoder | |
Normal force measurment design (US Pat. 6167752,1996) |
- | - | 360 ° capacitive sensor, non-contacting, fully integrated in bearing |
Working mode | - | Combined Motor Transducer (CMT) | |
Minimum torque (rotation) |
nNm | 1 µNm | 5 |
Minimum torque (oscillation) |
nNm | 1 µNm | 2 |
Maximum torque | mNm | 125 | 200 |
Minimum angular deflection (set value) |
µrad | 1 | 0.5 |
Maximum angular deflection (set value) |
µrad | ∞ | ∞ |
Minimum angular velocity[1] | rad/s | 0 | 0 |
Maximum angular velocity | rad/s | 157 | 314 |
Maximum speed | 1/min | 1500 | 3000 |
Minimum speed (CSS/CSR) | 1/min | 10-3 | 10-7 |
Minimum angular frequency[2] | rad/s | 10-4 | 10-7 |
Maximum angular frequency | rad/s | 628 | 628 |
Maximum frequency[3] | HZ | 100 | 100 |
Normal force range | N | - | -50 to 50 |
Normal force sensitivity | N | - | 0.01 |
Minimum gap size change | µm | 0.625 | 0.625 |
Dimensions (W x H x D) | mm | 380 x 660 x 530 | 444 x 678 x 586 |
Weight | kg | 33 | 42 |
Additional Device Features | |||
Device display with remote control of software (decoupled from measuring sensor for mechanical and electromagnetic interference prevention) | - | Yes | Yes |
Direct strain/stress controller | - | Yes | Yes |
TruStrain™(sample adaptive controller) | - | No | Yes |
TruRate™ (sample adaptive controller) | - | No | Optional |
Raw data (LAOS, waveform) | - | No | Optional |
Normal force profiles (set and read) | - | No | Yes |
Velocity profiles, tack, squeeze | - | No | Yes |
Automatic gap control/setting (AGC/AGS) | - | Yes | Yes |
Electronic trim lock for measuring geometry | - | Yes | Yes |
TruGap™ (permanent control of the real measuring gap) (US Pat. 6499336, 2000) |
- | No | Optional |
T-Ready™ (detection of sample temperature equilibrium time) (US Pat. 8904852, 2011)[4] |
- | No | Yes |
Toolmaster™ (measuring geometries and accessories, storing of zero-gap) (US Pat. 7275419, 2004) |
- | Yes | Yes |
QuickConnect Coupling for measuring geometries (one-hand operation, screwless) |
- | Yes | Yes |
Trimming mirror (360° blind sample spot prevention) |
- | No | Yes |
Three-point support of device (three robust feet for tool-free one hand alignment) |
- | Yes | Yes |
Three-point support for mounting of measuring cells (wobble prevention, no misalignment after changing of cells) |
- | Yes | Yes |
Maximum temperature range[4] | °C | -50 to +400 | -160 to +1000 |
Virtually gradient-free temperature control (horizontal,vertical) |
- | Yes | Yes |
Temperature gradient >0.1 °C according to AASHTO and ASTM | - | Yes | Yes |
CoolPeltier™ Peltier System with built-in cooling option that does not require additional accessories for counter cooling | °C | -5 to +200 | -5 to +200 |
Pressure Cell | bar | No | up to 1000 |
Safe Gap™ normal force limiter during gap setting | - | Yes | No |
TruRay™ dimmable illumination of sample area | - | Yes | No |
RheoCompass Software | |||
Asphalt standard operation procedures (SOP) with regular updates | - | Yes | Yes |
Auto Update via Network | - | Optional | Optional |
Fully automatic temperature calibration | - | Yes | Yes |
Test and analysis designer | - | Yes | Yes |
Report designer (with all test information for export and print) |
- | Yes | Yes |
Managed lab multiple clients and servers | - | Optional | Optional |
To contact Anton Paar Australia about Anton Paar Dynamic Shear Rheometer | SmartPave use Get a quote.
The well-established SmartPave dynamic shear rheometers are able to analyze unmodified and modified asphalt binder and bitumen within a wide temperature range, either according to standards or by means of classic rheological methods. While SmartPave 102e is the instrument which meets the highest measurement demands, SmartPave 92 is designed especially for the demands of quality control and routine measurements in asphalt test labs.
RheoCompass is a navigation tool that gives you the complete overview as well as the exact insights you require. It contains numerous templates that are tailored specifically to the needs of the asphalt industry. The predefined test procedures contain step-by-step instructions for all test types as defined by AASHTO, ASTM, DIN EN, and FGSV.
SmartPave 92’s and SmartPave 102e’s unique temperature control unit is the first Peltier heating system with heating elements above and below the sample. Furthermore, the instruments feature Toolmaster™ – the only completely contact-free automatic tool recognition and configuration system for rheometers. It recognizes measuring systems and temperature control units as soon as they are connected to the rheometer. Entering your data manually will become a thing of the past.
Anton Paar offers fully automatic temperature calibration and verification routines in the RheoCompass software. Temperature accuracy and stability are crucial in asphalt testing. The unique automatic temperature calibration routine ensures temperature gradients <0.1 °C.
Enhance your SmartPave 102e or 92 with a specialized software solution from our cooperation partner, Pavement Systems LLC. Connect effortlessly to this external analysis software and unlock a range of features, including iCCL testing. This is a powerful surrogate method to BBR (AASHTO PP112), which gives you information about the low temperature PG-grade as well as m-value, S, and delta TC within 30 minutes. Learn more about Pavement Systems and their analysis solutions.
Anton Paar’s worldwide service network ensures that an expert on your system is always close by. Numerous installed instruments around the globe, an extensive application database, and cooperation with civil engineering institutes confirm that Anton Paar is the first choice for answering any rheological question on your asphalt binder and bitumen you might have.
Technical Data | Unit | SmartPave 92 | SmartPave 102e |
Bearing design | - | Air, fine-pored carbon | |
Motor design | - | Electronically Commutated (EC) - Permanent Magnet Synchronous Motor | |
Displacement transducer design | - | High-resolution optical encoder | |
Normal force measurment design (US Pat. 6167752,1996) |
- | - | 360 ° capacitive sensor, non-contacting, fully integrated in bearing |
Working mode | - | Combined Motor Transducer (CMT) | |
Minimum torque (rotation) |
nNm | 1 µNm | 5 |
Minimum torque (oscillation) |
nNm | 1 µNm | 2 |
Maximum torque | mNm | 125 | 200 |
Minimum angular deflection (set value) |
µrad | 1 | 0.5 |
Maximum angular deflection (set value) |
µrad | ∞ | ∞ |
Minimum angular velocity[1] | rad/s | 0 | 0 |
Maximum angular velocity | rad/s | 157 | 314 |
Maximum speed | 1/min | 1500 | 3000 |
Minimum speed (CSS/CSR) | 1/min | 10-3 | 10-7 |
Minimum angular frequency[2] | rad/s | 10-4 | 10-7 |
Maximum angular frequency | rad/s | 628 | 628 |
Maximum frequency[3] | HZ | 100 | 100 |
Normal force range | N | - | -50 to 50 |
Normal force sensitivity | N | - | 0.01 |
Minimum gap size change | µm | 0.625 | 0.625 |
Dimensions (W x H x D) | mm | 380 x 660 x 530 | 444 x 678 x 586 |
Weight | kg | 33 | 42 |
Additional Device Features | |||
Device display with remote control of software (decoupled from measuring sensor for mechanical and electromagnetic interference prevention) | - | Yes | Yes |
Direct strain/stress controller | - | Yes | Yes |
TruStrain™(sample adaptive controller) | - | No | Yes |
TruRate™ (sample adaptive controller) | - | No | Optional |
Raw data (LAOS, waveform) | - | No | Optional |
Normal force profiles (set and read) | - | No | Yes |
Velocity profiles, tack, squeeze | - | No | Yes |
Automatic gap control/setting (AGC/AGS) | - | Yes | Yes |
Electronic trim lock for measuring geometry | - | Yes | Yes |
TruGap™ (permanent control of the real measuring gap) (US Pat. 6499336, 2000) |
- | No | Optional |
T-Ready™ (detection of sample temperature equilibrium time) (US Pat. 8904852, 2011)[4] |
- | No | Yes |
Toolmaster™ (measuring geometries and accessories, storing of zero-gap) (US Pat. 7275419, 2004) |
- | Yes | Yes |
QuickConnect Coupling for measuring geometries (one-hand operation, screwless) |
- | Yes | Yes |
Trimming mirror (360° blind sample spot prevention) |
- | No | Yes |
Three-point support of device (three robust feet for tool-free one hand alignment) |
- | Yes | Yes |
Three-point support for mounting of measuring cells (wobble prevention, no misalignment after changing of cells) |
- | Yes | Yes |
Maximum temperature range[4] | °C | -50 to +400 | -160 to +1000 |
Virtually gradient-free temperature control (horizontal,vertical) |
- | Yes | Yes |
Temperature gradient >0.1 °C according to AASHTO and ASTM | - | Yes | Yes |
CoolPeltier™ Peltier System with built-in cooling option that does not require additional accessories for counter cooling | °C | -5 to +200 | -5 to +200 |
Pressure Cell | bar | No | up to 1000 |
Safe Gap™ normal force limiter during gap setting | - | Yes | No |
TruRay™ dimmable illumination of sample area | - | Yes | No |
RheoCompass Software | |||
Asphalt standard operation procedures (SOP) with regular updates | - | Yes | Yes |
Auto Update via Network | - | Optional | Optional |
Fully automatic temperature calibration | - | Yes | Yes |
Test and analysis designer | - | Yes | Yes |
Report designer (with all test information for export and print) |
- | Yes | Yes |
Managed lab multiple clients and servers | - | Optional | Optional |
To contact Anton Paar Australia about Anton Paar Dynamic Shear Rheometer | SmartPave use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product