The device supports Modbus RTU and ASCII protocols. 64 channels for data querying and archiving are available. The logger is equipped with four (0)4-20 mA analog inputs. The data are stored on an SD card. The integrated USB port enables data reading and device configuration. Use of the included programming tool makes the configuration and data handling easy and comfortable.
Functions and features:
Areas of application:
The MSD200 can be used for data archiving in various processes in the food, chemical, gas and packaging industry as well as in the construction materials and wood processing industries. It can be also applied in many other areas of industrial and building automation.
Specifications
Power supply |
24 (20...32) V DC |
Power consumption, max. |
5 W |
Number of channels, max. |
64 |
Logging cycle |
1…65535 s |
Dataset size (per 1 channel) |
20 byte |
Storage media |
MMC, SD, SDHC, microSD |
Storage capacity |
=32 GB |
Storage medium file system |
FAT32 |
Analog inputs |
|
Quantity |
4 |
Input signals |
0-5 mA, 0(4)-20 mA |
Sampling time for analog inputs |
100 ms |
Accuracy |
±1.0% |
Input resistance |
133 ohm |
Galvanic isolation |
none |
Resolution |
12 bit |
Communication |
|
Interfaces |
2 x RS485 (RS1, RS2) |
Protocol |
Modbus RTU / ASCII, akYtec |
RS485 |
|
RS1 operation mode |
Slave (PC interface) |
RS2 operation mode |
Master (Device interface) |
RS1 protocol |
Modbus RTU |
RS2 protocol |
Modbus RTU / ASCII, akYtec |
Baud rate |
1.2...115.2 kBit/s |
Galvanic isolation |
individual |
Environment |
|
Ambient temperature |
-10...+55 °C |
Humidity |
up to 80%, non-condensing |
IP Code |
IP20 |
Enclosure |
|
Dimensions |
22.5 x 102 x 120 mm |
Weight |
approx. 150 g |
Material |
plastic |
***If you are not sure what you need, give us a call and quote IndustrySearch to discuss your needs with qualified engineers.
To contact Autech Control Group about akYtec MSD200 Data logger use Get a quote.
The device supports Modbus RTU and ASCII protocols. 64 channels for data querying and archiving are available. The logger is equipped with four (0)4-20 mA analog inputs. The data are stored on an SD card. The integrated USB port enables data reading and device configuration. Use of the included programming tool makes the configuration and data handling easy and comfortable.
Functions and features:
Areas of application:
The MSD200 can be used for data archiving in various processes in the food, chemical, gas and packaging industry as well as in the construction materials and wood processing industries. It can be also applied in many other areas of industrial and building automation.
Specifications
Power supply |
24 (20...32) V DC |
Power consumption, max. |
5 W |
Number of channels, max. |
64 |
Logging cycle |
1…65535 s |
Dataset size (per 1 channel) |
20 byte |
Storage media |
MMC, SD, SDHC, microSD |
Storage capacity |
=32 GB |
Storage medium file system |
FAT32 |
Analog inputs |
|
Quantity |
4 |
Input signals |
0-5 mA, 0(4)-20 mA |
Sampling time for analog inputs |
100 ms |
Accuracy |
±1.0% |
Input resistance |
133 ohm |
Galvanic isolation |
none |
Resolution |
12 bit |
Communication |
|
Interfaces |
2 x RS485 (RS1, RS2) |
Protocol |
Modbus RTU / ASCII, akYtec |
RS485 |
|
RS1 operation mode |
Slave (PC interface) |
RS2 operation mode |
Master (Device interface) |
RS1 protocol |
Modbus RTU |
RS2 protocol |
Modbus RTU / ASCII, akYtec |
Baud rate |
1.2...115.2 kBit/s |
Galvanic isolation |
individual |
Environment |
|
Ambient temperature |
-10...+55 °C |
Humidity |
up to 80%, non-condensing |
IP Code |
IP20 |
Enclosure |
|
Dimensions |
22.5 x 102 x 120 mm |
Weight |
approx. 150 g |
Material |
plastic |
***If you are not sure what you need, give us a call and quote IndustrySearch to discuss your needs with qualified engineers.